You may have seen the latest chemical news from the United States. 68 drums of the primary explosive lead azide, stored in a bunker at the Iowa Army Ammunition Plant, have been improperly cared for. Because of the shock-sensitivity of the compound as well as the quantity involved (well over 4000kg), the decision has been made to destroy the material in place. By the time you read this, the detonation will likely have happened.
This is a tragedy. Lead is a potent neurotoxin. While the authorities have hopefully done all that can be done to prevent a large dust cloud (such as piling additional dirt on top of and around the bunkers and spraying water to weigh down the dust), it is clear that there will be a release of lead into the surrounding farms and homes in the area. There is no safe level for human exposure to lead, and so even as those towns and residences will be evacuated and surfaces cleaned to the best of the government and the townspeople’s abilities, it will be many, many years before the families that live in those homes sleep soundly without thought about environmental toxins.
What is the chemistry around why this happened? Metal azides are highly reactive, as the three nitrogens bonded together would very much like to disproportionate and become simply molecular nitrogen gas. Sodium azide was used for many years as a propellant for automobile airbags, but stopped because of the toxic impact of old airbags leaking into the environment. Lead azide was used as a ‘primary explosive’ or the explosive that is used to set off the main charge of secondary explosives, such as TNT. To be stored for travel or transport, lead azide is ‘wetted’ with ethanol and water to make it less sensitive.
Over the years, it appears that these drums of lead azide in Iowa were stored in underground bunkers and the water and ethanol have either evaporated (leaving solid lead azide that is more sensitive) or worse yet, recrystallised, where the heating and cooling over the years has allowed for the crystals of lead azide in the drums to dissolve and then grow larger. These larger crystals are known to be even more shock-sensitive.
How could this have been avoided?
Like all tragedies, there are multiple causes. It is obvious that making too much of a primary explosive is, in the long run, a bad thing. Economics typically drives these decisions to manufacture more of a chemical product and store it, with the thought that the manufacturing costs can be spread over a larger volume. Continuous chemical manufacturing technology, with its smaller physical footprint, should allow for primary explosive synthesis to be done at much smaller practical volumes and closer to the actual point of use.
I am also surprised at the decisions not to dispose of this material sooner. Once it was known that such a dangerous primary explosive was not being used, it should have been destroyed. It is too easy for writers behind a keyboard to point fingers at people in the past, but various chemical disposal techniques could have been employed. Sodium azide can be destroyed upon exposure to nitrous acid, and it seems very reasonable to presume that lead azide would be similarly oxidised to harmless nitrogen (there is the non-trivial matter of where to bury the remaining lead waste.) There is a chemical company in the United States that is using sodium hydrosulfite as a reductant to destroy nitro-based explosives and it claims that it has been able to safely dispose of lead azide as well.
It is my hope that we can take this as a signature lesson in what not to do in our laboratories and chemical plants
It is also obvious that the excess material was not stored correctly. As the people of Burlington, Iowa are all too aware, the 68 drums of lead azide have crystallised out due to improper storage. Proper temperature and humidity control of the warehouses were as essential to keeping the residents living around the ammunition plant safe, just as much as thick concrete berms and distance were. It is shocking to me that there was apparently not more of an effort to monitor the storage of this material and to keep it (relatively) inert. Proper temperature and humidity control is something we have the technology for a long, long time – humidifiers, dehumidifiers and air conditioners have been with us for decades – but we apparently chose not to use them appropriately in Iowa, with potentially catastrophic results.
It is my hope that we, as a chemical community, can take this as a signature lesson in what not to do in our laboratories and chemical plants – don’t accumulate excess materials, dispose of unwanted reagents promptly and store things correctly. It keeps our labs tidy and safe and can prevent tragedies like this one.